YUKEN BST BSG Solenoid Controlled Relief Valves BST-03 BST-06 BST-10 BSG-03 BSG-06 BSG-10
These valves are a combination of a pilot operated relief valve and a solenoid operated directional valve. Piping between the two is eliminated as the solenoid valve is directly mounted on the relief valve and connected with the relief valve vent. Pump pressure may be unloaded remotely by an electrical signal to the solenoid, or by connecting pilot relief valves to the solenoid valve ports. To adjust the pressure, loosen the lock nut and turn the handle slowly clockwise for higher pressures or anti-clockwise for lower pressures. After adjustments, do not forget to tighten the lock nut. Piping of the tank line should not be connected to any tank line of the other valves, but connected directly to the reservoir. Pressure is limited by collars fitted. If a working pressure cannot be attained, remove some collars. One collar is equivalent to 10 MPa (1450 PSI). With a small flow, the setting pressure may be unstable. Use models numbered 03 and 06 with a flow rate above 8 L/min (2.1 U.S. GPM) and model 10 with 15 L/min (4.0 U.S. GPM).


|
YUKEN BST BSG Solenoid Controlled Relief Valves BST-03 BST-06 BST-10 BSG-03 BSG-06 BSG-10 |







|
|

Hot Tags: yuken bst bsg solenoid controlled relief valves bst-03 bst-06 bst-10 bsg-03 bsg-06 bsg-10, China yuken bst bsg solenoid controlled relief valves bst-03 bst-06 bst-10 bsg-03 bsg-06 bsg-10 manufacturers, suppliers, factory