
PVS Pump Parker PVS Series Hydraulic Vane Pump
NOMINAL DISPLACEMENT:8.3 12.8 16 24 31 40 51.5mL/r RATED PRESSURE:14MPa MAXIMUM PRESSURE:14MPa RATED SPEED:1000-1800r/min SPEED RANGE:1000-1800r/min Fluid recommendations Premium quality hydraulic mineral oil fluids are recommend, like H-LP oils to DIN 51524, part 2. The viscosity range should be 25 to 50 mm2/s (cSt) at 50 0C. Normal operating viscosity range between 12 and 100mm2/s (cSt). Maximum start-up viscositiy is 800 mm2/s(cSt). Operating temperature -30 to + 70 0C. For other fluids such as phosphoric acid esters or for other operating conditions consult your Parker representative for assistance. Seals NBR (nitrile) seals are use for operation with hydraulic fluids based on mineral oil. For synthetic fluids, as perhaps phosphoric acid esters, Fluorocarbon seals are required. Consult your Parker representative for assistance. Drain line The drain line must lead directly to the reservoir without restriction. The drain line must not connect to any other return line. The end of the drain line must be below the lowest fluid level in the reservoir and as far away as possible from the pump inlet line. This ensures that the pump does not empty itself when not in operation and that hot aireat oil will not recirculat. For the same reason, when the pump is mount inside the reservoir, the drain line should arrang in such a way that a siphon is created. This ensures that the pump always fill with fluid. The drain pressure must not exceed 2 bar. Drain line length should not exceed 2 metres. Minimum diameter should select according to the port size and a straight low pressure fitting with maximised bore should use. Filtration For maximum pump and system component functionability and life, the system should be protected from contamination by effective filtration. Fluid cleanliness should be in accordance with ISO classification ISO 4406:1999. The quality of filter elements should be in accordance with ISO standards. Minimum requirement for filtration rate x (mm): General hydraulic systems for satisfactory operation: Class 20/18/15, to ISO 4406:1999 Hydraulic systems with maximised component life and functionability: Class 18/16/13, to ISO 4406:1999 It is recommended to use return line or pressure filters. Parker Filter Division offers a wide range of these filters for all common applications and mounting styles. The use of suction filters should be avoided, especially with fast response pumps. Bypass filtration is a good choice for best filter efficiency. Installation and mounting Horizontal mounting: Outlet port side or top. Inlet port side or bottom, drain port always uppermost. Vertical mounting: Shaft pointing upwards. Install pump and suction line in such a way that the maximum inlet pressure never exceeds 0.8 bar absolute. The inlet line should be as short and as straight as possible. A short suction line cut to 450 is recommended when the pump is mounted inside the reservoir, to improve the inlet conditions. All connections to be leak-free, as air in the suction line will cause cavitation, noise, and damage to the pump. Drain port Compensation may cause short-term (20 to 30 ms) flow increase, e.g. 30 l/min (PV 016 to 023), 40 l/min (PV 032 to 046), 60 l/min (PV 063 to 092),80 l/min (PV 140 to 180) and/or 120 l/min (PV270). Please consider for dimensioning. Shaft rotation and alignment Pump and motor shafts must be aligned within 0.25mm T.I.R. maximum. A floating coupling must be used. Bellhousings and couplings can be ordered at manufacturers listed in this catalogue. Please follow the coupling manufacturer’s installation instructions. Consult your Parker representative for assistance on radial load type drives. Start up Prior to start up, the pump case must be filled with hydraulic fluid (use case drain port). Initial start up should be at zero pressure with an open circuit to enable the pump to prime. Pressure should only be increased once the pump has been fully primed. Attention: Check motor rotation direction. For more details see PVS pump installation manual PVS50EH140C2 PVS08AZ140 PVS08EH140 PVS12AZ140 PVS12AZ140C2 PVS12EH140 PVS12EH140C2 PVS16AZ140 PVS16AZ140C2 PVS16EH140 PVS16EH140C2 PVS16EH140C2Z PVS16EH140Z PVS25AZ140 PVS25AZ140C2 PVS25EH140 PVS25EH140C2 PVS25EH140C2Z PVS25EH140C2Z PVS32AZ140 PVS32AZ140C2 PVS32EH140 PVS32EH140C2 PVS32EH140C2Z PVS32EH140Z PVS40AZ140 PVS40EH140
|
||||||||

Hot Tags: pvs pump parker pvs series hydraulic vane pump, China pvs pump parker pvs series hydraulic vane pump manufacturers, suppliers, factory, REXROTH Hydraulic Axial Piston Variable Motor A6VE A6VE107, HKS Hydraulic Rotary Actuators M DA H F3 M DA H, LINDE Hydraulic Pump HPV 02 HHPR 02 16, Rexroth Axial Piston Variable MotorA6VM AA6VM Hydraulic Motor, GHP3 GEAR PUMP, KAYABA Piston Pump PSV PSVD PSVL

